Porous Metal Collectors Extended Battery Life in an Avrion Lab Test
Addionics reported on November 18 that cylindrical lithium-ion cells built and tested at Avrion Battery Labs reached about 3.5 times as many cycles as reference cells before falling to 80% state of health.
Published November 19, 2026Briefs / Energy / Advanced Battery Tech

Addionics reported on November 18 that cylindrical lithium-ion cells built and tested at Avrion Battery Labs reached about 3.5 times as many cycles as reference cells before falling to 80% state of health. Both groups used the same graphite and nickel-rich NMC811 electrode chemistries. The comparison tested a change to the metal that carries current from the electrodes.
The lab charged and discharged the 2.7 amp-hour cells at a nominal one-hour rate at 25°C, with a 48-hour rest after every 20 cycles. Addionics also reported faster recovery during the pauses. The results describe one company-reported cell comparison under that schedule.
A conventional current collector is a flat metal foil. Addionics uses a porous metal structure that extends into the electrode. The company proposes that the geometry helps dissolved salt even out through the electrolyte after cycling. The study tracked capacity and electrical resistance; direct measurements of salt distribution remain planned.
The rest schedule puts the result in perspective. Ten 48-hour pauses amount to twenty days of rest over 200 cycles if all ten pauses are taken. During the initial recovery measurement, Addionics says its cells stabilized in under two hours, while reference cells needed more than 48. By cycle 200 its cells needed under twelve hours. For a machine that works several shifts, the shorter recovery could matter even before the battery reaches its end-of-life threshold. A buyer would still need the comparison under its actual charging windows. A two-day pause after every twentieth cycle is a substantial operating assumption for a machine sold on round-the-clock availability.
Earlier work on prismatic nickel-manganese-cobalt/graphite cells offers a reason to look closely at the pauses. Investigators found that some apparently lost capacity returned after storage and that the state of charge during cycling and rest mattered. Recoverable capacity complicates any attempt to assign the whole decline during rapid cycling to permanent chemical damage. It does not establish Addionics’ proposed salt-redistribution mechanism. The studies use different cells and schedules. Earlier capacity-recovery experiment
For a fleet operator, two comparisons would separate the benefits. Measure usable capacity at the end of a busy shift, then measure it after the actual overnight charging window. A collector that preserves more capacity by the end of the shift could keep a vehicle on the route. A cell that recovers more by morning could reduce how many spares the operator needs. Neither business outcome follows directly from a laboratory ratio measured at the 80% threshold.